精品人妻少妇嫩草AV无码专区,99精品丰满人妻无码一区二区,寡妇高潮一级毛片免费看,欧美婬乱片A片AAA毛姪片
上海沃華產(chǎn)品技術(shù)服務(wù)有限公司,為您提供一站式的注冊(cè)服務(wù)!全國(guó)統(tǒng)一免費(fèi)服務(wù)熱線(xiàn):400-016-1080   021-51088618 Chinese/English
服務(wù)范圍
美國(guó)FDA質(zhì)量管理體系QSR820咨詢(xún)返回首頁(yè)

QSR 820 法規(guī)從1996年發(fā)布以來(lái),歷史上進(jìn)行了6次小型的技術(shù)修改。如下

 

Technical Amendment
Federal Register Citation

65 FR 17136
(31-Mar-2000)

Change removed paragraphs (e) and (f) from 820.1 Scope.

PART 820—QUALITY SYSTEM REGULATION
7. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 351, 352, 360, 360c, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
8. Amend § 820.1 by removing paragraphs (e) and (f).


65 FR 66636
(07-Nov-2000)

Change restored paragraph (e) to 820.1 Scope.

 

PART 820—QUALITY SYSTEM REGULATION
5. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.
6. Section 820.1 is amended by adding paragraph (e) to read as follows:
§ 820.1 Scope.
* * * * *
(e) Exemptions or variances. (1) Any person who wishes to petition for an exemption or variance from any device quality system requirement is subject to the requirements of section 520(f)(2) of the act. Petitions for an exemption or variance shall be submitted according to the procedures set forth in § 10.30 of this chapter, the FDA’s administrative procedures. Guidance is available from the Center for Devices and Radiological Health, Division of Small Manufacturers Assistance (HFZ–220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1–800–638–2041 or 1–301–443–6597, FAX 301–443–8818.

(2) FDA may initiate and grant a variance from any device quality system requirement when the agency determines that such variance is in the best interest of the public health. Such variance will remain in effect only so long as there remains a public health need for the device and the device would not likely be made sufficiently available without the variance.


69 FR 11313
(10-Mar-2004)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

 

PART 820—QUALITY SYSTEM REGULATION
14. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l 371, 374, 381, 383.
15. Section 820.198(d) is revised to read as follows
§ 820.198 Complaint files.
* * * * *
(d) Any complaint that represents an event which must be reported to FDA under part 803 of this chapter shall be promptly reviewed, evaluated, and investigated by a designated individual(s) and shall be maintained in a separate portion of the complaint files or otherwise clearly identified. In addition to the information required by § 820.198(e), records of investigation under this paragraph shall include a determination of:
(1) Whether the device failed to meet specifications;
(2) Whether the device was being used for treatment or diagnosis; and
(3) The relationship, if any, of the device to the reported incident or adverse event.
* * * * *
16. Section 820.200(c) is revised to read as follows:
§ 820.200 Servicing.
* * * * *

c) Each manufacturer who receives a service report that represents an event which must be reported to FDA under part 803 of this chapter shall automatically consider the report a complaint and shall process it in accordance with the requirements of § 820.198.


69 FR 29829
(25-May-2004)

Changed to specifically note applicability of 21

CFR 820 to tissue products, under newly released 21 CFR 1271.

Also, the Quality System regulation contains a typographic error: it has a date of 2005, but 2004 is the correct date.

 

PART 820—QUALITY SYSTEM REGULATION
6. The authority citation for 21 CFR part 820 is revised to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383; 42 U.S.C. 216, 262, 263a, 264.
7. Section 820.1 is amended by adding two sentences to the end of paragraph (a)(1), and by revising paragraph (b) to read as follows:
§ 820.1 Scope.
(a) Applicability. (1) * * *
Manufacturers of human cells, tissues, and cellular and tissue-based products (HCT/Ps), as defined in § 1271.3(d) of this chapter, that are medical devices (subject to premarket review or notification, or exempt from notification, under an application submitted under the device provisions of the act or under a biological product license application under section 351 of the Public Health Service Act) are subject to this part and are also subject to the donor-eligibility procedures set forth in part 1271 subpart C of this chapter and applicable current good tissue practice procedures in part 1271 subpart D of this chapter. In the event of a conflict between applicable regulations in part 1271 and in other parts of this chapter, the regulation specifically applicable to the device in question shall supersede the more general.
* * * * *
(b) The quality system regulation in this part supplements regulations in other parts of this chapter except where explicitly stated otherwise. In the event of a conflict between applicable regulations in this part and in other parts of this chapter, the regulations specifically applicable to the device in question shall supersede any other generally applicable requirements.


71 FR 16228
(31-Mar-2006)

Change removed reference to 21 CFR 804, which was deleted from the CFR.

PART 820—QUALITY SYSTEM REGULATION
3. The authority citation for 21 CFR part 820 continues to read as follows:
Authority: 21 U.S.C. 351, 352, 360, 360c, 360d, 360e, 360h, 360i, 360j, 360l, 371, 374, 381, 383.

4. Amend paragraph (a)(3) of § 820.198 by removing ‘‘or 804’’.


72 FR 17397
(09-Apr-2007)

Change updated title, address, and phone numbers for DSMICA.

PART 820—QUALITY SYSTEM REGULATION

6. FDA is revising Sec.  820.1(e) and replacing “Division of Small Manufacturers Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 1-301-443-6597, FAX 301-443-8818” with “Division of Small Manufacturers, International and Consumer Assistance (HFZ-220), 1350 Piccard Dr., Rockville, MD 20850, U.S.A., telephone 1-800-638-2041 or 240-276-3150, FAX 240-276-3151.”

企業(yè)介紹 | 法律聲明 | 網(wǎng)站地圖 | 認(rèn)證查詢(xún) | 資料下載 | 在線(xiàn)留言 | 聯(lián)系方式
上海沃華產(chǎn)品技術(shù)服務(wù)有限公司 Copyright 2025 m.smhvat.com, 版權(quán)所有 滬ICP備16037738號(hào)-1
電話(huà):021-51088618;400-016-1080 地址:上海市長(zhǎng)寧區(qū)天山路641號(hào)慧谷白貓科技園1號(hào)樓701室
友情鏈接: CE認(rèn)證 | BIM咨詢(xún) | 深圳注冊(cè)公司

滬公網(wǎng)安備 31010502002363號(hào)


欧美亚洲国产精品久久高清浪潮 | 91亚洲精品国偷拍自产在线观看 | 色狠狠色噜噜AV天堂五区消防 | 亚洲免费精品视频 | 国产一区二区精品丝袜 | 日本在线视频观看 | 少妇性按摩无码中文A片 | 亚洲综合激情五月久久 | 熟女人妻的婬乱和放荡 | 国产精品视频一区二区三区, | 婷婷国产一区二区三区四区 | 国产成人精品 视频 | 欧美又粗又大AAA片 几人强行糟蹋人妻HD | 国产浓毛大泬熟妇视频 | 无码人妻精品一区二区蜜桃视频 | 波多野结衣在线无码视频 | 秘 亚洲国产精品成人网站 国产寡妇婬乱A毛片视频 | 91人妻人人澡人人爽人人精品乱 | 绿帽人妻-ThePorn | 欧美丰满少妇猛烈进入A片蜜桃 | 亚州人成Va影院 | 久久久成人一区二区 | 九一精品人妻人人操 | 摸BBB揉BBB揉BBB高清视频 | 国产一级一片免费播放放a 96精品无码一区二区动漫 | 亚洲爆乳无码精品AAA片蜜桃 | 人妻少妇精品无码专区 | 国产极品国模粉嫩小泬 | 朝鲜揉BBB搡BBB视频 | 久久99久久99精品 | 91丝袜 国产在线观看 | 国产一级A片免费视频 | 国产91精品秘入口福利姬 | 少妞躁BBB少妞躁BBBB | 91精品久久久久久久久久浪潮 | 国产成人a亚洲精品无码青草-百度 | 国产成人精品 视频 | 中国少妇自慰成人A片 | 久久99久久99精品蜜柚传媒 | 91人妻人人澡人人爽精品萌萝社 | 少妇被躁到高潮无码a片游戏 |